Residential BESS

NEO Casa

High Voltage Stackable ESS for Home Application

图片关键词

 Description

With its modular design, the Multi-functional Energy Storage System offers endless possibilities. Customize the system to meet your specific needs by easily adding or removing energy storage units. Experience the freedom and control of managing your energy consumption with this state-of-the-art system.

NEO Casa Technical Data

Model

SER-HVL

SER-HVH

Performance Specs

Nominal Voltage (Vdc)

51.2

51.2

Nominal Capacity (Wh)

2560

5120

Working Voltage Range (Vdc)

129.6-516.6

129.6-350.4

Charge Voltage (Vdc)

56.16

56.16

Nominal Charge/Discharge Current(A)

25

50

Max. Charge/Discharge Current(A)

50

100

Peak Current(A)

100@3sec

200@3sec

Series Connection

3-10 pcs

3-6 pcs

Cycle Life

6000 @ 80% DOD, 25°C / 0.5C

General Specs

Power Module Dimensions(mm)/Weight(kg)

600*210*250 /14

610*225*250 /15

Battery Module Dimensions(mm)/Weight(kg)

600*210*160 /27

610*225*250 /52

Lampstand Module Dimensions(mm)/Weight(kg)

600*210*90 /5

610*225*90 /5.5

Top Cap Module Dimensions(mm)/Weight(kg)

600*210*50 /2.5

610*225*50 /3

IP Rating

IP65

Installation

Stacked

Charge Working Temperature(°C)

0-55

Discharge Working Temperature(°C)

-20~60

Altitude (M)

<2500

Humidity (RH)

5-95% (w/o condensing)

Communication Port

RS485, CAN

Display

SOC status indicator, LED indicator

Certification

CB, IEC62619, CE-EMC, CE-GPSD, UKCA, UL1973, UL9540A, EN62040, IEC62040; UN38.3, MSDS



NEO Casa

Low Voltage Stackable ESS for EU Home Application

图片关键词


Description

With its modular design, the Multi-functional Energy Storage System offers endless possibilities. Customize the system to meet your specific needs by easily adding or removing energy storage units. Experience the freedom and control of managing your energy consumption with this state-of-the-art system.

NEO Casa Technical Data

ModelSER-LV
Performance Specs
Nominal Voltage (Vdc)51.2
Nominal Capacity (Wh)5120
Working Voltage Range (Vdc)44.8-56.16
Charge Voltage (Vdc)58.4
Nominal Charge/Discharge Current(A)50
Max. Charge/Discharge Current(A)100
Peak Current(A)200@3sec
Parallel Connection  ≤ 6 pcs
Cycle Life6000 @ 80% DOD, 25°C / 0.5C
General Specs
Dimension(mm)600*210*300
Weight(kg)50.5
IP RatingIP65
InstallationStacked
Charge Working Temperature(°C)0-55
Discharge Working Temperature(°C)-20~60
Altitude (M)<2500
Humidity (RH)5-95% (w/o condensing)
Communication PortRS485, CAN
DisplaySOC status indicator, LED indicator
Certification
CB, IEC62619; CE-EMC, CE-GPSD, UKCA; UN38.3, MSDS



NEO Tota

All-in-One Three Phase ESS for EU Home Application

图片关键词

Description

Sidus AF Series is an all-in-one solar and storage solution that integrates the inverter, battery charger, UPS-level switching, and battery enclosure into a pre- wired modular system for easier and faster installation. The compact, elegantly designed, and robust unit is IP66 rated, so it can be mounted either inside or outside withstanding all weather conditions and brings a reduction of installation time of up to 50%.

NEO Tota Inverter Technical Data

Mode

SHE-AF3KSHE-AF4KSHE-AF5KSHE-AF6KSHE-AF8KSHE-AF10KSHE-AF12KSHE-AF15K
PV Input
Max DC Input Power (kW)567.5912151822.5

DC Input Voltage Range (V)

150-1000

MPPT Voltage Range (V)

150-850

Start-up Voltage (V)

160

Max DC Input Current (A)

20 x 2

Max Short Current (A)

30 x 2

No. of MPPT Tracker/Strings

2 / 2

Battery Input

Battery Nominal Voltage (V)

150200200250300350450500

Battery Voltage Range (V)

80-600

Max Charge/Discharge Current (A)

30

Max Charge/Discharge Power (kW)

34568101215

Compatible Battery Type

Li-ion / Sodium-ion / LFP

AC Grid

Nominal AC Output Power (kW)

34568101215

Max AC Output Current (A)

5.378.510.513.51721.527

Nominal AC Voltage (V)

230 / 400

Nominal AC Frequency (Hz)

50 / 60

Power Factor

1 ( -0.8 to +0.8) adjustable

Current THD

<3%

AC Load Output (Backup)

Nominal Output Power (VA)

30004000500060008000100001200015000

Nominal Output Voltage (V)

230 / 400

Nominal Output Frequency (Hz)

50 / 60

Nominal Output Current (A)

4.45.87.38.711.614.517.421.8

Peak Output Power (60s)

3300VA4400VA5500VA6600VA8800VA11000VA13200VA16500VA

THDV (with linear load)

< 3%

Switching Time (ms)

≤ 10

Efficiency

Europe Efficiency

97.5%

Max Efficiency

98.0%98.2%98.3%

Bat. Charge/Discharge Eff.

98.0%

Protection

Reverse Polarity Protection

Yes

Over Current/Voltage

Yes

Anti-islanding

Yes

AC Short-circuit

Yes

Leakage Current Detection

Yes

Ground Fault Monitoring

Yes

Grid Monitoring

Yes

Enclosure Protect Level

IP66

AC/DC Surge Protection

Type II

General Data

Dimensions (W x H x D, mm)

600 x 432 x 210

Weight (kg)

25

Topology

Transformer less

Cooling Concept

Natural ConvectionIntelligent Fan

Relatively Humidity

Intelligent Fan

Operating Temp. Range (°C)

-25 to 60

Operating Altitude (m)

<4000

Standby Consumption (W)

<5

Display & Comm. Interfaces

LCD, LED, RS485, CAN, WIFI, GPRS, 4G

Cert. & Approvals

NRS097, G98/G99, EN50549-1, C10/C11, AS4777.2, VDE-AR-N4105, VDE0126, IEC62109-1, IEC62109-2, EN61000-6-2, EN61000-6-3

 NEO Tota Battery Technical Data 

图片关键词

3 Packs

4 Packs

5 Packs

6 Packs

7 Packs

8 Packs

9 Packs

10 Packs

7.68kWh

10.24kWh

12.8kWh

15.36kWh

17.92kWh

20.48kWh

23.04kWh

25.6kWh

 

ModelSER-HVL
Performance Specs
Nominal Voltage (Vdc)51.2
Nominal Capacity (Wh)2560
Working Voltage Range (Vdc)129.6-516.6
Charge Voltage (Vdc)56.16
Nominal Charge/Discharge Current(A)25
Max. Charge/Discharge Current(A)50
Peak Current(A)100@3sec
Series Connection3-10 pcs
Cycle Life6000 @ 80% DOD, 25°C / 0.5C
General Specs
Power Module Dimensions(mm)/Weight(kg)600*210*250 /14
Battery Module Dimensions(mm)/Weight(kg)600*210*160 /27
Lampstand Module Dimensions(mm)/Weight(kg)600*210*90 /5
Top Cap Module Dimensions(mm)/Weight(kg)600*210*50 /2.5
IP RatingIP65
InstallationStacked
Charge Working Temperature(°C)0-55
Discharge Working Temperature(°C)-20~60
Altitude (M)<2500
Humidity (RH)5-95% (w/o condensing)
Communication PortRS485, CAN
DisplaySOC status indicator, LED indicator
Certification
CB, IEC62619, CE-EMC, CE-GPSD, UKCA, UL1973, UL9540A, EN62040, IEC62040; UN38.3, MSDS



Split-Phase Hybrid Inverter

 图片关键词

Description

Sidus storage inverters are designed to increase energy independence for homeowners. The designed power is 6.0kW and 9.6kW, compatible with high voltage (80-495V) batteries. Energy management is based on time-of-use and demand charge rate structures, significantly reduce the amount of energy purchased from public grid. Thanks for the UPS function (switch time < 10ms), that it enables the crucial loads power on during outages. Additionally, under the backup operation mode, the inverter provides you up to 150% peak output overloading. The storage inverters meet the US safety regulations, integrated with Arc Fault Circuit Interrupter (AFCI) and Rapid Shutdown.

Model

SE06K-2P-N

SE10K-2PN

Battery Input Data

Battery Type

Lithium /Lead-acid

Battery Voltage Range (V)

80 - 495

Battery Normal Voltage (V)

230

Max. Charging/Discharging Current (A)

50

Charging Strategy for Li-ion Battery

Self-adaption to BMS

Number of Battery Input

1

PV String Input Data

Max. DC Input Power (kW)

9.0

15.0

Max. DC Input Voltage (V)

600

MPPT Voltage Range (V)

80~550

Max. Operating PV Input Current (A)

15.5 x 2

15.5 x 3

Max. Input Short-Circuit Current (A)

26.0 x 2

26.0 x 3

No. of MPP Trackers / No. of PV String

2 / 2

2 / 2

AC Input/Output Data

Rated AC Input/Output Power (kW)

6.0

9.6

Max. AC Input/Output Power (kW)

6.96

11.16

Rated Output Current (A)

25

40

Max. Output Current (A)

29

46.5

Max. Grid AC to Load Passthrough (A)

43.3

49.5

Peak Power (off-grid)

150%~20ms

Power Factor Adjustment Range

0.8 leading to 0.8 lagging

Rated Input/Output Voltage/Range (V)

110~120 (Single Phase), 110~120/220~240 (Split Phase)

Rated Input/Output Grid Frequency (Hz)

60

Grid Connection Form

2L + N + PE

Total Current Harmonic Distortion THDu

<3%

Efficiency

Max. Efficiency

97.6%

CEC Efficiency

97.0%

PV to Bat. Efficiency

98.1%

Equipment Protection

Integrated

PV Reverse Polarity Protection, Bat. Reverse Polarity Protection,

Over Current/Voltage Protection, Anti-Islanding Protection,

AC Short Circuit Protection, Residual Current Detection,

Ground Fault Monitoring, Insulation Resister Detection,

PV Arc Detection, Rapid Shut Down, Protection Degree, AC/DC surge protection (TYPE ll)

General Data

Operating Temperature Range ()

-25~+60

Relative humidity

0-95%

Operating Altitude

≤4000m

UPS Switching Time (ms)

< 10

Ingress protection

IP65/NEMA 3R

Cooling Mode

FAN cooling

Display

LCD

Topology

Transformer less

Dimensions W*H*D (mm)

400 x 600 x 229

Weight (kg)

25kg

Standby consumption

< 10W

Communication with BMS/Meter/EMS

RS485, CAN

Supported communication interface

RS485, WLAN, 4G (optional)

Warranty

5 Years/10 Years (Optional extensions)

Grid Regulation

IEEE1547, IEEE1547A, IEEE1547.1, Rule21, HECO Rule 14

Safety

UL 1741 SA, UL 1741, UL1699B, UL 1998, CSA 22.2 No.107

EMC Standard

FCC part 15 class B